Coretec says it has developed a time-tested alternative to nitrogen blanketing for easy, effective corrosion protection of void spaces in idle equipment and permanent structures.
VpCI-337 fille a major need in the oil and gas industry, and any other industry that deals with metal tanks, piping, boilers, heat exchangers, hollow metal structures, or even hard-to-reach areas between the layers of metal coils, the company said.
Nitrogen purge challenges
Nitrogen purge or nitrogen blanketing is commonly used to protect metal void spaces from corrosion by replacing the oxygen with nitrogen gas. However, there are three challenges to the success and efficiency of this method.
First of all, nitrogen gas is expensive, raising a cost barrier, especially where large spaces are concerned, Coretec maintained. The second challenge is nitrogen requires constant pressure with an airtight seal. This necessitates regular monitoring and complete reapplication if a leak occurs. Third, leaks also pose a safety hazard for personnel who unknowingly enter an area where deadly gas has settled, and may be overcome in moments.
VpCI-337 advantages
By contrast, VpCI-337 is much safer, cost-effective, and easy to apply and maintain, according to the company.
VpCI-337 is a waterborne vapor phase corrosion inhibitor that can be applied by fogging into metal void spaces. This labor-saving technique uses a minimum of product to protect large areas or volumes. Vapor phase corrosion inhibitors in the fogging fluid diffuse throughout the void and are attracted to metal surfaces where they “condense” and form a protective molecular layer. This layer inhibits the corrosion reaction on the metal surfaces even in the presence of oxygen and residual moisture. The space must be completely closed for the corrosion inhibitors to be effective, but an air-tight seal is not required as for nitrogen purge.
At the end of the preservation period, there is usually no need to remove the VpCI layer— although this is easily done if needed.
Scope of use
Another advantage of VpCI-337 is its versatility. VpCI-337 can provide corrosion protection for everything from massive heat recovery steam generators to small crates of metal parts. Coretec says the following are real-life examples of how VpCI-337 has been used:
- Internal preservation of pig receivers enroute from construction yard to offshore installation site
- One-year protection of aboveground storage tank internals at a sulfur recovery plant
- Preservation of spare heat-exchanger tube bundles (in conjunction with VpCI-132 and MilCorr VpCI Shrink Film) previously stored in nitrogen pressurized canisters
- Temporary protection of fuel tanks in retired aircraft stored outdoors during museum renovation
- Transit protection of automotive frames shipped inside sea containers (VpCI-337 fogged inside VpCI-126 Film covered skids)
- Protective packaging element used for shipment of horizontally opposed piston aircraft engines
VpCI-337 also is an option for manufacturer edge treatment of coils, fogging of oil drilling risers, internal protection of metal tubular structures, and more.
Visit cortecvci.com for more information.